<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>انجمن آب و فاضلاب ایران</PublisherName>
				<JournalTitle>علوم و مهندسی آب و فاضلاب</JournalTitle>
				<Issn>2588-3941</Issn>
				<Volume>11</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>A Review of Operational Methods for Preventing Silica Scaling in Water Treatment Plants</ArticleTitle>
<VernacularTitle>مروری بر روش‎های عملیاتی به‎منظور پیش‎گیری از بروز رسوبات سیلیس در واحدهای تصفیه آب</VernacularTitle>
			<FirstPage>4</FirstPage>
			<LastPage>16</LastPage>
			<ELocationID EIdType="pii">233925</ELocationID>
			
<ELocationID EIdType="doi">10.22112/jwwse.2025.525769.1455</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>کورش</FirstName>
					<LastName>اسفندیاری</LastName>
<Affiliation>استادیار دانشکده مهندسی شیمی، دانشگاه علم و فناوری مازندران، بهشهر، ایران.</Affiliation>
<Identifier Source="ORCID">0000-0002-0957-3361</Identifier>

</Author>
<Author>
					<FirstName>اشکان</FirstName>
					<LastName>اربابی</LastName>
<Affiliation>شرکت فناور ایمن لوتوس، شهرک صنعتی آق‌قلا، گرگان، ایران.</Affiliation>

</Author>
<Author>
					<FirstName>حامد</FirstName>
					<LastName>صفاریان</LastName>
<Affiliation>شرکت فناور ایمن لوتوس، شهرک صنعتی آق‌قلا، گرگان، ایران.</Affiliation>
<Identifier Source="ORCID">0000-0002-0298-8126</Identifier>

</Author>
<Author>
					<FirstName>رامین</FirstName>
					<LastName>زارعی</LastName>
<Affiliation>شرکت فناور ایمن لوتوس، شهرک صنعتی آق‌قلا، گرگان، ایران.</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2025</Year>
					<Month>05</Month>
					<Day>27</Day>
				</PubDate>
			</History>
		<Abstract>&lt;span&gt;Water scarcity has driven the widespread adoption of Reverse Osmosis (RO) membrane processes for water purification. In reverse osmosis plants, water is pressurized and passes through a semi-permeable membrane and the impurities are separated and the pure water is generated. However, the formation of mineral scale on the membrane surface significantly reduces the technology&#039;s efficiency, shortens membrane lifespan, and increases operational costs. Silica, a common water impurity, precipitates due to the polymerization of silicic acid. Since silica scale removal is challenging and often requires strong, environmentally harmful chemical cleaners, preventing its formation is crucial. Preventive strategies include membrane surface modification, adjusting the pH and temperature of the feed water to increase silica solubility, reducing the concentration of other contributing minerals, pre-treating feed water to lower silica concentration, and using appropriate antiscalants to inhibit silica polymerization. This review article examines the latest operational research to compile practical solutions for experts managing reverse osmosis water treatment facilities.&lt;/span&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;span lang=&quot;FA&quot;&gt;با توجه به چالش&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;های کمبود آب، فرآیندهای غشایی اسمز معکوس برای تصفیه آب گسترش یافته&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;اند. در این روش، آب با فشار از غشای نیمه&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;تراوا عبور کرده و ناخالصی&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;ها جدا می&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;شوند. با این&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;حال، تشکیل رسوب املاح موجود در آب بر سطح غشا، کارایی این فناوری را کاهش&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;داده، عمر مفید غشا را کم و هزینه&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;ها را افزایش می&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;دهد. سیلیس، از رایج&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;ترین املاح آب، در اثر پلیمریزاسیون اسید&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;سیلیسیک رسوب می&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;کند. از آن&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;جایی&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;که حذف رسوبات سیلیس دشوار و نیازمند شوینده&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;های شیمیایی قوی و مضر برای محیط&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;زیست است، پیش&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;گیری از تشکیل رسوب سیلیس از اهمیت بالایی برخوردار است. راه&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;کارهای پیش&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;گیرانه شامل اصلاح سطح غشا، تنظیم&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt; &lt;/span&gt;&lt;span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;و دمای آب ورودی برای افزایش انحلال&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;پذیری سیلیس، کاهش غلظت سایر املاح موجود در آب که به تشکیل رسوب کمک می&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;کنند، پیش&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;تصفیه آب ورودی برای کاهش غلظت سیلیس و استفاده از آنتی&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;اسکالانت&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;های مناسب برای ممانعت از پلیمریزاسیون سیلیس است. لذا در این مقاله مروری، تلاش شده است ضمن بررسی آخرین پژوهش&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;های موجود از دیدگاه عملیاتی، راهکارهای عملیاتی مناسب برای استفاده توسط کارشناسان واحدهای تصفیه آب به روش اسمز معکوس مورد جمع&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;بندی قرارگیرد.&lt;/span&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">تصفیه آب</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">جداسازی غشایی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">اسمز معکوس</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">رسوبات سیلیس</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">آنتی اسکالانت</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.jwwse.ir/article_233925_1ec9da02cac72c5c4816e27c5ff8eb43.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>انجمن آب و فاضلاب ایران</PublisherName>
				<JournalTitle>علوم و مهندسی آب و فاضلاب</JournalTitle>
				<Issn>2588-3941</Issn>
				<Volume>11</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Optimization of Bioremediation Alternatives in Petroleum-Contaminated Aquifers: A Case Study of Shiraz Oil Refinery</ArticleTitle>
<VernacularTitle>بهینه‌سازی گزینه های زیست‌‌پالایی در آبخوان‌های آلوده نفتی: مطالعه موردی پالایشگاه نفت شیراز</VernacularTitle>
			<FirstPage>17</FirstPage>
			<LastPage>32</LastPage>
			<ELocationID EIdType="pii">236913</ELocationID>
			
<ELocationID EIdType="doi">10.22112/jwwse.2025.485324.1416</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>سروش</FirstName>
					<LastName>امیراکبری</LastName>
<Affiliation>دانشجوی دکتری، دانشکده مهندسی عمران، آب و محیط‎زیست، دانشگاه شهید بهشتی، تهران، ایران.</Affiliation>
<Identifier Source="ORCID">0009-0007-1350-520X</Identifier>

</Author>
<Author>
					<FirstName>سعید</FirstName>
					<LastName>علیمحمدی</LastName>
<Affiliation>دانشیار دانشکده مهندسی عمران، آب و محیط‎زیست، دانشگاه شهید بهشتی، تهران، ایران.</Affiliation>
<Identifier Source="ORCID">0000-0002-4421-3353</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>11</Month>
					<Day>03</Day>
				</PubDate>
			</History>
		<Abstract>&lt;span&gt;In this study, a simulation-optimization model was developed to minimize the cost of bioremediation in a petroleum-contaminated aquifer. Groundwater flow and contaminant transport were simulated using MODFLOW6 and MT3D-USGS, while bioremediation optimization was performed using the differential evolution algorithm. The accuracy of the modeling approach was verified through a benchmark test. Subsequently, the Shiraz Oil Refinery was selected as a case study, and the remediation of BTEX (benzene, toluene, ethylbenzene, and xylene) contamination resulting from a potential spill was evaluated under four scenarios. The results of Scenario 1 indicated that natural bioremediation alone could not reduce benzene concentrations to the regulatory limit. The other three scenarios were defined based on the location, number of bioremediation wells, and remediation duration. In all three cases, the contaminant concentration was reduced below the regulatory standard by the end of the ten-year period. Optimization results showed that Scenario 2 (with two injection wells and two extraction wells over four years) had the lowest total cost of $157,634, making it 12.1% cheaper than Scenario 3 and 9.5% cheaper than Scenario 4. In contrast, Scenario 3 exhibited the fastest remediation rate. In summary, Scenario 2 was the most cost-effective option due to its lower bioremediation cost and lower pumping and injection rates over a longer duration, whereas Scenario 3 was more effective in achieving rapid remediation.&lt;/span&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;span lang=&quot;FA&quot;&gt;در این پژوهش، یک مدل شبیه‌سازی-بهینه­سازی با هدف حداقل‌سازی هزینه زیست‌پالایی در یک آبخوان آلوده نفتی، ارائه شده است. شبیه­سازی جریان و آلودگی با مدل‌های &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;MODFLOW6&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;، &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;MT3D-USGS&lt;/span&gt;&lt;span&gt; &lt;span lang=&quot;FA&quot;&gt;و بهینه‌سازی زیست‌پالایی با الگوریتم تکامل تفاضلی انجام شد و صحت مدل‌سازی با یک مسئله آزمون کنترل شد. در ادامه پالایشگاه شیراز به&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;عنوان مطالعه موردی انتخاب و پاکسازی آلودگی &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;BTEX&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; (بنزن، تولوئن، اتیل‌بنزن و زایلن)، حاصل از نشت محتمل در چهار گزینه بررسی شد. نتایج گزینه 1 نشان داد که زیست‌پالایی طبیعی قادر به کاهش غلظت آلاینده بنزن تا مقدار مجاز نیست. سه گزینه دیگر براساس موقعیت، تعداد چاه­های زیست‌پالایی و مدت زمان اجرا تعریف شدند و در هر سه گزینه، غلظت آلاینده در انتهای دوره ده ساله، به کمتر غلظت استاندارد رسید. نتایج بهینه‌سازی نشان&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;داد که سناریوی دوم (با ۲ چاه تزریق و ۲ چاه پمپاژ، طی 4 سال) با هزینه کل 157634 دلار، 1/%12&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;ارزان‌تر از گزینه سوم و 5/9 درصد ارزان‌تر از گزینه چهارم است. در مقابل، گزینه سوم سریع‌ترین نرخ پاک‌سازی را داشت. به&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;طور خلاصه، گزینه دوم هزینه پاکسازی کمتری داشته و به&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;علت طولانی‌تر بودن اجرا، نرخ پمپاژ و تغذیه کمتری نیز دارد، و گزینه‌ سوم دارای اثربخشی پاک‌سازی سریع‌تری است.&lt;/span&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">پاکسازی آب زیرزمینی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">BTEX</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">زیست‌پالایی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">پالایشگاه شیراز</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">الگوریتم تکامل تفاضلی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">MODFLOW6</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">MT3D-USGS</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.jwwse.ir/article_236913_71623f649e28cf55f7f1e5326311c458.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>انجمن آب و فاضلاب ایران</PublisherName>
				<JournalTitle>علوم و مهندسی آب و فاضلاب</JournalTitle>
				<Issn>2588-3941</Issn>
				<Volume>11</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Optimization of Antibiotic Reduction Process from Hospital Wastewater Using UASB Reactor</ArticleTitle>
<VernacularTitle>بهینه‎سازی فرآیند کاهش آنتی‎بیوتیک­ از پساب بیمارستان با استفاده از راکتور UASB</VernacularTitle>
			<FirstPage>33</FirstPage>
			<LastPage>46</LastPage>
			<ELocationID EIdType="pii">225999</ELocationID>
			
<ELocationID EIdType="doi">10.22112/jwwse.2025.498528.1429</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>امیر علی</FirstName>
					<LastName>عمادی خیاو</LastName>
<Affiliation>دانشجوی مقطع دکتری مهندسی محیط‎زیست، گرایش آب و فاضلاب، دانشکده هنر، معماری، عمران و محیط‎زیست، دانشگاه آزاد اسلامی واحد تهران غرب، تهران، ایران.</Affiliation>

</Author>
<Author>
					<FirstName>رویا</FirstName>
					<LastName>مافی غلامی</LastName>
<Affiliation>استاد گروه محیط‎زیست آب و فاضلاب، واحد تهران غرب، دانشگاه آزاد اسلامی، تهران، ایران.</Affiliation>
<Identifier Source="ORCID">0000-0003-1566-5569</Identifier>

</Author>
<Author>
					<FirstName>اصغر</FirstName>
					<LastName>داود</LastName>
<Affiliation>دانشیار، گروه شیمی دارویی، واحد علوم پزشکی، دانشگاه آزاد اسلامی، تهران، ایران.</Affiliation>

</Author>
<Author>
					<FirstName>امیر حسین</FirstName>
					<LastName>محوی</LastName>
<Affiliation>دانشیار، گروه مهندسی بهداشت محیط، دانشگاه علوم پزشکی تهران، تهران، ایران.</Affiliation>

</Author>
<Author>
					<FirstName>لیدا</FirstName>
					<LastName>سلیمی</LastName>
<Affiliation>استادیار، گروه مهندسی محیط‎زیست، دانشگاه آزاد اسلامی (تهران شمال)، تهران، ایران.</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2025</Year>
					<Month>01</Month>
					<Day>20</Day>
				</PubDate>
			</History>
		<Abstract>&lt;span lang=&quot;EN&quot;&gt;The introduction of antibiotics into the river system regardless of proper treatment leads to the increase of bacterial resistance, genotoxicity and genetic disorders in the society, hence the implementation of efficient treatment in medical centers is very important. In this study, the establishment of an upward flow anaerobic sludge reactor or UASB was investigated in order to remove antibiotics from hospital wastewater. The reactor was started using activated sludge from the hospital. In order to start the reactor, the sludge was soaked for 48 hours. The amount of antibiotics injected was azithromycin 5.2 mg/liter and ceftriaxone 6.7 mg/liter.&lt;/span&gt; &lt;span lang=&quot;EN&quot;&gt;The optimal conditions of reactor activity were 6 hrs of hydraulic retention time, pH 6, cell retention time of 30 days and temperature of 25 &lt;sup&gt;o&lt;/sup&gt;C, in which COD removal efficiency was 81.58&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;%&lt;/span&gt;&lt;span lang=&quot;EN&quot;&gt;, BOD 83.12&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;%&lt;/span&gt;&lt;span lang=&quot;EN&quot;&gt;, the removal percentage of azithromycin antibiotic 86.35&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;%&lt;/span&gt;&lt;span lang=&quot;EN&quot;&gt; and the removal percentage of ceftriaxone antibiotic 874/52&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;%&lt;/span&gt;&lt;span lang=&quot;EN&quot;&gt;. The successful efficiency of the system in reducing the antibiotic load of wastewater and the lack of sludge removal from this system has turned this system into a clean system for the environment. &lt;/span&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;span lang=&quot;FA&quot;&gt;ورود آنتی&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;بیوتیک­ها به سیستم رودخانه بدون توجه به تصفیه مناسب، زمینه افزایش مقاومت باکتریایی، ژئوتوکسیسیتی و اختلالات ژنتیکی را جامعه به&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;دنبال دارد. از این&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;رو اجرای تصفیه­ای کارآمد در مراکز درمانی اهمیت بالایی دارد. در این پژوهش راه­اندازی راکتور لجن بی­هوازی جریان رو به بالا یا &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;UASB&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; به&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;منظور حذف آنتی­بیوتیک از فاضلاب بیمارستانی مورد بررسی قرارگرفته است. پکیج تصفیه فاضلاب &lt;/span&gt; &lt;span dir=&quot;LTR&quot;&gt;UASB&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;یکی از سیستم&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;­&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;های&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;تصفیه فاضلاب&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;است که برپایه استفاده از میکروارگانیسم&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;­&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;ها در شرایط بی&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;هوازی برای حذف آلاینده&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;­&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;های آلی موجود در فاضلاب&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;­&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; طراحی شده است&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;.&lt;/span&gt;&lt;strong&gt; &lt;/strong&gt;&lt;span lang=&quot;FA&quot;&gt;راه­اندازی راکتور با استفاده از لجن فعال بیمارستان انجام شد. به&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;منظور راه­اندازی راکتور، لجن به&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;مدت 48 ساعت سازگاری داده&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;شد. در این مطالعه تاثیر تغییرات &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; (محدوده­ بین 4 تا 8)، درجه حرارت (25-40 درجه سانتی&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;گراد)، زمان ماند هیدرولیکی (4 تا 8 ساعت)، زمان ماند سلولی (محدوده­ بین 20 تا 40 روز) بر روی درصد حذف &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;COD&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;، &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;BOD&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; و حذف آنتی&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;بیوتیک­ها مورد مطالعه قرارگرفت. میزان تزریق آنتی­بیوتیک­ها آزیترومایسین 2/5 میلی­گرم بر لیتر و سفتریاکسون 7/6 میلی­گرم بر لیتر بود. شرایط بهینه فعالیت راکتور در شرایط 6 ساعت زمان ماند هیدرولیکی، &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; 6، زمان ماند سلولی 30 روز و دمای 25 درجه سانتی­گراد بود که در این شرایط راندمان حذف &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;COD&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; برابر 58/81 درصد، &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;BOD&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; برابر 12/83 درصد، حذف آنتی­بیوتیک آزیترومایسین برابر 35/86 درصد و حذف آنتی­بیوتیک سفتریاکسون برابر 52/874 درصد بود. درنتیجه کارایی موفق سیستم در کاهش بار آنتی­بیوتیکی فاضلاب و عدم دفع لجن، این سیستم را به سیستمی پاک برای محیط&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;زیست تبدیل کرده است. &lt;/span&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">آنتی بیوتیک</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">تصفیه بی­هوازی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">راکتور لجن بی­هوازی جریان رو به بالا</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">فاضلاب بیمارستانی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.jwwse.ir/article_225999_6a7e18de32d3bd2531c328fb58ef4e11.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>انجمن آب و فاضلاب ایران</PublisherName>
				<JournalTitle>علوم و مهندسی آب و فاضلاب</JournalTitle>
				<Issn>2588-3941</Issn>
				<Volume>11</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Evaluation of Decision Variable Vector Modeling Methods in Multiphase Optimal Design of Water Distribution Networks</ArticleTitle>
<VernacularTitle>ارزیابی روش‌های مدل‌سازی بردار متغیر تصمیم در طراحی بهینه چندفازی شبکه‌های توزیع آب</VernacularTitle>
			<FirstPage>47</FirstPage>
			<LastPage>62</LastPage>
			<ELocationID EIdType="pii">234577</ELocationID>
			
<ELocationID EIdType="doi">10.22112/jwwse.2025.515624.1450</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>محمدمهدی</FirstName>
					<LastName>ریاحی</LastName>
<Affiliation>دانش آموخته دکتری مهندسی عمران، دانشکده‌ عمران و معماری دانشگاه شهیدچمران اهواز، اهواز، ایران.</Affiliation>
<Identifier Source="ORCID">0000-0002-4133-7705</Identifier>

</Author>
<Author>
					<FirstName>امین</FirstName>
					<LastName>ابراهیم بخشی پور</LastName>
<Affiliation>محقق، دپارتمان مدیریت آب شهری، دانشگاه کایزرسلاترن، کایزرسلاترن، آلمان.</Affiliation>

</Author>
<Author>
					<FirstName>کارلو</FirstName>
					<LastName>جودیچیانی</LastName>
<Affiliation>استادیار، گروه مهندسی عمران و معماری، دانشگاه پاویا، پاویا، ایتالیا.</Affiliation>

</Author>
<Author>
					<FirstName>علی</FirstName>
					<LastName>حقیقی</LastName>
<Affiliation>استاد دانشکده‌ عمران و معماری، دانشگاه شهیدچمران اهواز، اهواز، ایران.</Affiliation>

</Author>
<Author>
					<FirstName>انریکو</FirstName>
					<LastName>کریاکو</LastName>
<Affiliation>استاد، گروه مهندسی عمران و معماری، دانشگاه پاویا، پاویا، ایتالیا.</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2025</Year>
					<Month>04</Month>
					<Day>12</Day>
				</PubDate>
			</History>
		<Abstract>Unlike the static design, a traditional method that completes the design step in one phase, the dynamic method divides the design period into various phases. Nowadays, multi-objective optimization algorithms are employed to achieve optimal designs in the dynamic method. This research explains the multiphase design and construction, a sub-method of the dynamic method. Subsequently, two distinct approaches, namely the aggregated model and the disaggregated model, are introduced for modeling the decision variable vector in the multi-objective optimization algorithm. The aggregated model utilizes a single chromosome for each phase, while the disaggregated model employs two separate chromosomes for each phase. Finally, the effects of different approaches of decision variable vectors modelling applied to the dynamic method are investigated. The results demonstrated that the disaggregated model leads to a 10% improvement in the final Pareto front solutions compared to the aggregated model. Furthermore, this model resulted in a 6% increase in the number of final Pareto front solutions and a 2-fold increase in the number of feasible solutions in the initial iterations compared to the aggregated model.</Abstract>
			<OtherAbstract Language="FA">&lt;span lang=&quot;FA&quot;&gt;برخلاف روش طراحی استاتیکی که رویکردی سنتی محسوب می‌شود و فرآیند طراحی شبکه آبرسانی را در یک مرحله به انجام می‌رساند، روش طراحی دینامیکی با تقسیم‌بندی دوره طرح به فازهای متعدد، طراحی شبکه توزیع آب را انجام می&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;دهد. امروزه به‌منظور دستیابی به طرح‌های بهینه در روش طراحی دینامیکی، الگوریتم‌های بهینه‌سازی چندهدفه مورد استفاده قرار می‌گیرند. در پژوهش حاضر، ابتدا روش طراحی و ساخت چندفازی که زیرمجموعه‌ای از طراحی دینامیکی است، تشریح شده است. سپس، دو رویکرد متمایز مدل تجمیعی و مدل تفکیکی برای مدل‌سازی بردار متغیرهای تصمیم‌گیری در الگوریتم بهینه‌سازی چندهدفه معرفی می‌شوند. مدل تجمیعی در هر فاز از یک کروموزوم واحد استفاده می‌کند، در حالی&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;که مدل تفکیکی برای هر فاز از دو کروموزوم مجزا بهره می‌گیرد. در نهایت، تأثیراتی که این دو رویکرد مدل‌سازی بردار متغیرهای تصمیم‌گیری بر طراحی چندفازی شبکه‌های آبرسانی اعمال می‌نمایند، مورد مقایسه و ارزیابی قرار می‌گیرند. نتایج نشان می‌دهد که مدل تفکیکی منجر به بهبود ۱۰ درصدی جواب‌های جبهه پارتوی نهایی نسبت به مدل تجمیعی شده است. علاوه&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;بر این، این مدل موجب افزایش ۶ درصدی تعداد جواب‌های نهایی جبهه پارتو و افزایش ۲ برابری تعداد جواب‌های امکان‌پذیر در تکرارهای ابتدایی در مقایسه با مدل تجمیعی شده است. &lt;/span&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">شبکه‌های توزیع آب</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">بهینه سازی چندهدفه</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">طراحی استاتیکی و دینامیکی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">روش‌ چندفازبندی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.jwwse.ir/article_234577_f0107d3c1e280de61b14d6d50a2b9c88.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>انجمن آب و فاضلاب ایران</PublisherName>
				<JournalTitle>علوم و مهندسی آب و فاضلاب</JournalTitle>
				<Issn>2588-3941</Issn>
				<Volume>11</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>The Influence of Tungsten Oxide Nanorods on Water Flux, Salt Rejection, and Antifouling Performance of Polyethersulfone Membranes</ArticleTitle>
<VernacularTitle>تأثیر نانومیله‌های اکسید تنگستن بر شار آب، دفع نمک و خاصیت ضدگرفتگی غشاهای پلی‌اتر سولفون</VernacularTitle>
			<FirstPage>63</FirstPage>
			<LastPage>74</LastPage>
			<ELocationID EIdType="pii">244381</ELocationID>
			
<ELocationID EIdType="doi">10.22112/jwwse.2026.555045.1466</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>نازنین</FirstName>
					<LastName>همنبرد</LastName>
<Affiliation>دانشجوی دکتری، گروه شیمی، دانشکده علوم پایه، دانشگاه بین‎المللی امام خمینی (ره)، قزوین، ایران.</Affiliation>

</Author>
<Author>
					<FirstName>مریم</FirstName>
					<LastName>درگاهی</LastName>
<Affiliation>دانشیار گروه شیمی، دانشکده علوم پایه، دانشگاه بین‎المللی امام خمینی (ره)، قزوین، ایران.</Affiliation>
<Identifier Source="ORCID">0000-0002-5312-1311</Identifier>

</Author>
<Author>
					<FirstName>عباس</FirstName>
					<LastName>اکبرزاده</LastName>
<Affiliation>استادیار مرکز تحقیقات آب و فاضلاب، موسسه تحقیقات آب وزارت نیرو، تهران، ایران.</Affiliation>
<Identifier Source="ORCID">0000-0001-8942-6881</Identifier>

</Author>
<Author>
					<FirstName>علیرضا</FirstName>
					<LastName>ولیپور مرندی</LastName>
<Affiliation>کارشناس ارشد پژوهشی، سرپرست مرکز تحقیقات آب و فاضلاب، موسسه تحقیقات آب وزارت نیرو، تهران، ایران.</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2025</Year>
					<Month>10</Month>
					<Day>27</Day>
				</PubDate>
			</History>
		<Abstract>&lt;span&gt;In this study, tungsten oxide (WO₃) nanorods were synthesized via a hydrothermal method and thoroughly characterized using various techniques. Subsequently, 0.1 wt% of these nanorods was incorporated into polyethersulfone (PES) membranes to enhance their structural and functional properties. Structural and surface analyses indicated that the addition of WO₃ nanorods to the pristine PES membrane (Mbare) led to an increase in water contact angle, surface roughness, and porosity, accompanied by a reduction in pore size. These modifications are attributed to the high hydrophilicity and rod-like morphology of WO₃, which increase pore density and reduce pore radius. Performance evaluation revealed that the modified membrane (MWO₃) exhibited improved salt rejection and antifouling characteristics. At a pressure of 4 bar, the water flux of MWO₃ reached 14.81 L·m⁻²·h⁻¹, while the rejection rates for Na₂SO₄ and NaCl were 62.94% and 34.97%, respectively, demonstrating significant enhancement over the pristine membrane. In antifouling tests, MWO₃ achieved a Flux Recovery Ratio (FRR) of 71.57% and an irreversible fouling rate of 28.42%, compared to 51.24% FRR and 48.75% irreversible fouling for Mbare. Overall, the incorporation of WO₃ nanorods effectively improved the hydrophilicity, water flux, antifouling performance, and salt rejection of PES membranes, highlighting their potential for advanced water treatment applications. &lt;/span&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;span lang=&quot;FA&quot;&gt;در این پژوهش، نانومیله‌های اکسید تنگستن &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;(&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;WO₃&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;)&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;به&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;روش هیدروترمال سنتز و با استفاده از روش­های مختلف شناسایی شدند. در ادامه از نانو ذرات سنتز شده به&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;میزان 1/0 درصد وزنی برای اصلاح و ساخت غشای پلی‌اتر سولفون &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;(&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;PES&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;)&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;، استفاده شد. نتایج بررسی‌های ساختاری و سطحی نشان&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;داد افزودن نانومیله‌های&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;WO₃&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;به غشای خالص &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;(Mbare) PES &lt;/span&gt;&lt;span&gt;&lt;span&gt; &lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;موجب کاهش زاویه تماس، زبری سطح و تخلخل و در عین&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;حال کاهش اندازه منافذ شد. این تغییرات به&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;دلیل آب&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;دوستی بالای &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;WO₃&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;و مورفولوژی میله‌ای شکل آن است که افزایش تعداد حفرات و کاهش شعاع منافذ را شامل می­شود. نتایج کارایی و عملکرد دفع نمک و گرفتگی&lt;span&gt;  &lt;/span&gt;غشای اصلاح&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;شده &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;MWO₃&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;بیانگر آن است که در فشار ۴ بار، شار آب آن &lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;&lt;span&gt; &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;L·m⁻²·h⁻¹&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;81/14 &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;بوده و درصد دفع نمک&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;Na₂SO₄&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;و&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;NaCl&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;به‌ترتیب 94/62% و 97/34% به‌دست آمد که نسبت به غشای خالص بهبود یافته است. در آزمون ضدگرفتگی نیز غشای&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;MWO₃&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;دارای نرخ بازیابی شار &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;(&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;FRR&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;)&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;برابر 57/71%&lt;span&gt; &lt;/span&gt;و گرفتگی غیرقابل بازگشت 42/28% بود، در حالی‌که این مقادیر برای &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;Mbare&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;به‌ترتیب 24/51% و 75/48% گزارش شد. در مجموع، افزودن نانوذرات &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;WO₃&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;موجب افزایش آب&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;دوستی، شار آب، خاصیت ضدگرفتگی و دفع نمک در غشاهای &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;PES&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;می&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;شود.&lt;/span&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">اکسید تنگستن</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">نانو میله</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">غشای پلی‎اتر سولفون</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">دفع نمک</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">گرفتگی غشا</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.jwwse.ir/article_244381_9875c7c8970a465f640f3b7bc60d490f.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>انجمن آب و فاضلاب ایران</PublisherName>
				<JournalTitle>علوم و مهندسی آب و فاضلاب</JournalTitle>
				<Issn>2588-3941</Issn>
				<Volume>11</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>03</Month>
					<Day>21</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Optimization of Methyl Orange Removal from Aqueous Solutions Using Sol–Gel Synthesized TiO2-ZnO Nanophotocatalyst: Application of Response Surface Methodology (RSM)</ArticleTitle>
<VernacularTitle>بهینه‌سازی حذف متیل اورانژ از محلول‌ آبی با استفاده از نانو فتوکاتالیست TiO2-ZnO سنتز شده به‎روش سل-ژل: کاربرد روش سطح پاسخ (RSM</VernacularTitle>
			<FirstPage>75</FirstPage>
			<LastPage>91</LastPage>
			<ELocationID EIdType="pii">239721</ELocationID>
			
<ELocationID EIdType="doi">10.22112/jwwse.2026.540204.1459</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>سجاد</FirstName>
					<LastName>شهسواری</LastName>
<Affiliation>دانش‎آموخته کارشناسی ارشد، گروه مهندسی شیمی، دانشکده مهندسی، دانشگاه گلستان، علی‎آباد کتول، ایران.</Affiliation>

</Author>
<Author>
					<FirstName>محمد صالح</FirstName>
					<LastName>شفیعیان</LastName>
<Affiliation>استادیار گروه مهندسی شیمی، دانشکده مهندسی، دانشگاه گلستان، علی‎آباد کتول، ایران.</Affiliation>
<Identifier Source="ORCID">0000-0002-7798-2714</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2025</Year>
					<Month>08</Month>
					<Day>13</Day>
				</PubDate>
			</History>
		<Abstract>&lt;span&gt;In this study, TiO₂–ZnO nanocomposites were synthesized via the sol–gel method in three different weight ratios (1:3, 1:1, and 3:1) to enhance their photocatalytic performance. The synthesized nanocomposites were thoroughly characterized using X-Ray Diffraction (XRD), Field Emission Scanning Electron Microscopy (FESEM), Fourier Transform Infrared spectroscopy (FT-IR), and UV–Vis spectroscopy to evaluate their crystal structure, surface morphology, functional groups, optical band gap, and light absorption characteristics. The photocatalytic activity of the nanocomposites was investigated for the degradation of Methyl Orange (MO) dye in aqueous solution under Ultraviolet (UV) irradiation. Experimental design and statistical modeling were performed using Response Surface Methodology (RSM) based on Central Composite Design (CCD). The four input variables were varied within defined ranges, including UV light intensity (6-18 W), initial dye concentration (10-30 ppm), reaction time (0.2-5.5 hr), and catalyst dosage (0.1-1.9 g/L), and were used to develop the predictive regression model. The degradation of MO occurred predominantly through photocatalytic oxidation by the TiO&lt;sub&gt;2&lt;/sub&gt;–ZnO nanocomposite, and the pH of all experiments was maintained at a constant value of 4. Analysis of variance (ANOVA) confirmed the statistical significance and robustness of the developed quadratic regression model, with a high coefficient of determination (&lt;em&gt;R&lt;sup&gt;2&lt;/sup&gt;&lt;/em&gt; &gt; 0.99) and a &lt;em&gt;p&lt;/em&gt;-value below 0.0001, indicating excellent predictive capability and model accuracy. The optimal conditions for achieving the maximum dye removal efficiency of 96.36% were determined to be an initial dye concentration of 13.68 ppm, UVA irradiation at 17.55 W, a reaction time of 2.37 hr, and a catalyst dosage of 0.62 g/L. Enhanced light absorption in the UV region compared to individual TiO&lt;sub&gt;2&lt;/sub&gt; or ZnO nanoparticles demonstrated the superior photocatalytic performance of the synthesized TiO&lt;sub&gt;2&lt;/sub&gt;-ZnO nanocomposite in degrading the target organic pollutant.&lt;/span&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;span lang=&quot;AR-SA&quot;&gt;در این پژوهش، نانوکامپوزیت&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;TiO&lt;sub&gt;2&lt;/sub&gt;-ZnO&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;با هدف ارتقای عملکرد فتوکاتالیستی در سه نسبت وزنی متفاوت &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;)&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;1&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;:&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;3، 3&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;:&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;1 و 1&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;:&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;1&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;(&lt;/span&gt;&lt;span&gt; &lt;span lang=&quot;AR-SA&quot;&gt;به&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;AR-SA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;روش سل-ژل سنتز شد. &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;به‌منظور شناسایی &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;ساختار بلوری، مورفولوژی سطح، گروه‌های عاملی، گاف انرژی و خواص نوری نمونه‌ها از آزمون‌های پراش پرتو ایکس&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;(&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;XRD&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;)&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;،&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;میکروسکوپ الکترونی روبشی&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; گسیل میدانی&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;(&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;FESEM&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;)&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;،&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;طیف‌سنجی مادون قرمز با تبدیل فوریه&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;(&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;FT-IR&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;)&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;و طیف‌سنجی&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;UV-Vis&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;استفاده شد. کارایی فتوکاتالیستی نانوکامپوزیت‌های سنتزشده برای حذف رنگ متیل اورانژ&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;(&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;MO&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;)&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;از محلول آبی تحت تابش نور فرابنفش&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;(&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;UV&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;)&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;ارزیابی شد. در طراحی آزمایش‌ها از روش سطح پاسخ&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;(&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;RSM&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;)&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;مبتنی بر طراحی مرکب مرکزی&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;(CCD)&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;استفاده&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;AR-SA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;شد تا تأثیر چهار متغیر شامل &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;شدت تابش نور &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;(18-6 وات)&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;، غلظت اولیه رنگ&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;(&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;ppm&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;30-10)&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;، مدت زمان واکنش &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;(5/5-0/2 ساعت)&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; و مقدار کاتالیست &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;(1/9-0/0 گرم بر لیتر)&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; بر بازده حذف رنگ مورد بررسی و مدل&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;AR-SA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;سازی قرارگیرد. &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;حذف رنگ متیل اورانژ عمدتاً از طریق اکسیداسیون فتوکاتالیستی توسط نانوکامپوزیت &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;TiO&lt;sub&gt;2&lt;/sub&gt;-ZnO&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;صورت&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;FA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;گرفت و&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;آزمایش‌ها در مقدار ثابت 4 حفظ شد&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;. برپایه نتایج تحلیل واریانس، مدل رگرسیونی توسعه&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;‌&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;یافته با مقدار ضریب تعیین &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;(&lt;/span&gt;&lt;em&gt;&lt;span dir=&quot;LTR&quot;&gt;R&lt;sup&gt;2&lt;/sup&gt;&lt;/span&gt;&lt;/em&gt;&lt;span lang=&quot;AR-SA&quot;&gt;)&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;بیشتر از 99/0 و ضریب احتمال&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;(&lt;em&gt;p&lt;/em&gt;-value)&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;کمتر از 0001/0، تطابق و دقت آماری مناسبی را در پیش‌بینی راندمان حذف رنگ نشان&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;AR-SA&quot;&gt;‎&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;داد. شرایط بهینه برای دستیابی به حداکثر بازده حذف رنگ معادل 36/96%، شامل غلظت اولیه رنگ&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;ppm&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;68/13، شدت تابش&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;UVA&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;برابر با 55/17 وات، مدت زمان واکنش 37/2 ساعت و مقدار کاتالیست 62/0 گرم بر لیتر تعیین شد.&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;جذب نوری تقویت‌شده در ناحیه&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;UV&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;نسبت به هر یک از نانو ذرات منفرد&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;TiO&lt;sub&gt;2&lt;/sub&gt;&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;و&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;ZnO&lt;/span&gt;&lt;span&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;نشان‌دهنده کارایی بالای نانو&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;کامپوزیت&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; سنتز&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;‌شده در تجزیه این آلاینده‌ آلی است.&lt;/span&gt;&lt;span dir=&quot;LTR&quot; lang=&quot;AR-SA&quot;&gt; &lt;/span&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">نانوفتوکاتالیست</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">سل-ژل</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">TiO2</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">ZnO</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">متیل اورانژ</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">روش سطح پاسخ (RSM)</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.jwwse.ir/article_239721_8598757f55952f677dd19c8f8c3ec358.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
